Compaq uSign 200 Network Router User Manual


 
uSign User Manual
7.3.12 Start Capturing use FBP format 0
Command string: D6
Response string: D6
7.4 Multi-byte commands
7.4.1 Initialize device
Command string: 28 10 00 00
Response string: DC 05
7.4.2 Get PW120 Version
Command string: 2A 10 00 00
Response string: 01 00
7.4.3 Test device
Command string: 52 12 00 00
Response string: 52 12
7.4.4 Set CTS control
Command string: 22 15 01 00 01(enable)/00(disable)
Response string: 01
7.4.5 Set interval between two points
Command string: 28 15 01 00 xx
Response string: 01
7.4.6 Get data 0x00 0x01
Command string: 2A 15 00 00
Response string: 00 01
7.4.7 Calibrate the device
Command string: 30 15 00 00
Response string: 01
7.4.8 Set offset position
Command string: 31 15 04 00 xx xx xx xx(offset point)
Response string: 01
7.4.9 Get data 0x01
Command string: 32 15 00 00
Response string: 01
7.4.10 Offset using control
Command string: 34 15 01 00 01(enable)/00(disable)
Response string: 01
Copyright © 2006, International Technologies & Systems Corp. All rights reserved.
Page 15 of 18