CyberPower Systems CPS900AVR Power Supply User Manual


 
CPS900AVR
Guaranteed Uninterruptible Power System
EXPECTED RUNTIME IN MINUTES
Sample Systems
Load (Watts) CPS900AVR™ Model Runtime
75 96
125 64
150 49
200 35
250 26
300 19
350 15
400 12
450 8
500 4
REPLACING THE BATTERY
CAUTION!
Read and follow the
IMPORTANT SAFETY INSTRUCTIONS
before servicing the battery.
Service the battery under the supervision of
personnel knowledgeable of batteries and their precautions.
CAUTION! Use only the specified type of battery.
See your dealer for replacement batteries.
CAUTION!
The battery may present risk of electrical shock. Do not dispose of battery in a fire, as it may explode. Follow all local ordinances regarding
proper disposal of batteries.
CAUTION!
Do not open or mutilate the batteries. Released electrolyte is harmful to skin and eyes and may be toxic.
CAUTION!
A battery can present a high risk of short circuit current and electrical shock. Take the following precautions before replacing the battery:
1. Remove all watches, rings or other metal objects.
2. Only use tools with insulated handles.
3. Do not lay tools or metal parts on top of battery or any terminals.
4. Wear rubber gloves and boots.
5. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground.
CONTACT WITH GROUNDED
BATTERY CAN RESULT IN ELECTRICAL SHOCK!
The likelihood of such shock will be reduced if such grounds are removed during installation
and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit).
TO REPLACE THE BATTERY
1. Turn off and unplug all connected equipment.
2. Turn the UPS off and unplug it from the AC power source.
3. Turn the UPS upside down.
4. Remove the 6 retaining screws.
5. Turn the UPS right side up and remove the outlet cover.
6. Remove the battery from the compartment.
7. Disconnect the battery wires from the battery.
8. Install the replacement battery by connecting the
red wire to the positive (+) terminal of the battery
and connecting the
black wire to the
negative (-) terminal of the battery.
9. Slide the battery back into the compartment.
10. Replace the outlet cover and the 6 retaining screws.
11. Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime.
REMINDER:
Batteries are consider
HAZARDOUS WASTE
and must be disposed of properly. Contact your local government for more information
about proper disposal and recycling of batteries.
9
Desktop PC with 15” Monitor 54 - 65
Desktop PC with 17” Monitor 46 - 52
Desktop PC with 21” Monitor 36 - 44
Tower PC with 21” Monitor 30 - 38