CyberPower Systems CPS900AVR Power Supply User Manual


 
CPS900AVR
Guaranteed Uninterruptible Power System
As the battery discharges, the unit will beep more rapidly, indicating that the battery is nearing discharge. Once the test is complete, plug the UPS back in to
the AC outlet and start your computer. Please allow 4 hours for the UPS to recharge before attempting another self-test.
DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power
On
Wiring
Fault
AVR
Using
Battery
Check
Battery
Circuit
Breaker
Alarm
Condition
On Off Off Off Off Set Off Normal
On Off Flash Off Off Set Off
AVR-
AVR is maintaining a consistent 120v level (±5%)
during a power sag.
ON Off On Off Off Set Off
AVR-
AVR is maintaining a consistent 120v (±5%)
during a power surge
Off On/Off Off On Off Set Two Beeps
Utility Failure-
The UPS is providing battery power to
the Battery-Power Supplied outlets.
Off On/Off Off On Off Set Rapid Beeps
Utility Failure-
The UPS is providing battery power.
The rapid beeps indicate the battery will run out of
charge within a few minutes.
Off Off Off On Off Up Two beeps or rapid
beeps
Overload-
Occurs in the
Full-time Surge Protection
Outlets
. Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5 seconds,
reset the circuit breaker and turn the UPS on.
On/Off On/Off On/Flash/Off On/Off Off Set Long Beep
Overload-
Occurs in the
Battery-power Supplied
Outlets
. Turn the UPS off and unplug at least one piece
of equipment from the UPS. Wait 5 seconds, reset the
circuit breaker and turn the UPS on.
Off Off Off On Off Up Long Beep
Overload-
Occurs in the
Battery-power Supplied
Outlets
. Turn the UPS off and unplug at least one piece
of equipment from the UPS. Wait 5 seconds, reset the
circuit breaker and turn the UPS on.
On On/Off On/Flash/Off Off On Set None
Weak Battery-
Recharge the battery for at least 8
hours. If
Check Battery
is illuminated contact
CyberPower Systems for battery replacement
information.
Off Off Off Off Off Set Off
Surge Protection Malfunction-
Lightning induced
power line surge has damaged the surge-protect
function. Please contact CyberPower Systems
On/Off On/Off On/Flash/Off Flash Flash Set/Up Off
Scheduled Turn-on-
If the two battery indicators are
flashing in rotation, the UPS is waiting to turn on as
configured in the schedule.
On/Off On/Off On/Flash/Off Flash Flash Set/Up Three Beeps
Cold Start Disabled-
If the two battery indicators are
flashing at the same time, the cold-start has been
disabled. The UPS will not start in the absence of AC
power.
On/Off On On/Flash/Off On/Off On/Off Set/Up None
Electrical Wiring Fault-
This indicates a wiring a
problem such as a bad ground, missed ground or
reversed wiring
within the AC outlet
. User is advised
to disconnect all electrical equipment from the outlet and
have the outlet checked by an electrician.
7