CY7C1292DV18
CY7C1294DV18
Document #: 001-00350 Rev. *A Page 13 of 23
TAP AC Switching Characteristics Over the Operating Range
[13, 14]
Parameter Description Min. Max. Unit
t
TCYC
TCK Clock Cycle Time 50 ns
t
TF
TCK Clock Frequency 20 MHz
t
TH
TCK Clock HIGH 20 ns
t
TL
TCK Clock LOW 20 ns
Set-up Times
t
TMSS
TMS Set-up to TCK Clock Rise 5 ns
t
TDIS
TDI Set-up to TCK Clock Rise 5 ns
t
CS
Capture Set-up to TCK Rise 5 ns
Hold Times
t
TMSH
TMS Hold after TCK Clock Rise 5 ns
t
TDIH
TDI Hold after Clock Rise 5 ns
t
CH
Capture Hold after Clock Rise 5 ns
Output Times
t
TDOV
TCK Clock LOW to TDO Valid 10 ns
t
TDOX
TCK Clock LOW to TDO Invalid 0 ns
TAP Timing and Test Conditions
[13]
Notes:
13.Test conditions are specified using the load in TAP AC test conditions. t
R
/t
F
= 1 ns.
14.t
CS
and t
CH
refer to the set-up and hold time requirements of latching data from the boundary scan register.
(a)
TDO
C
L
= 20 pF
Z
0
= 50Ω
GND
0.9V
50Ω
1.8V
0V
ALL INPUT PULSES
0.9V
Test Clock
Test Mode Select
TCK
TMS
Test Data-In
TDI
Test Data-Out
t
TCYC
t
TMSH
t
TL
t
TH
t
TMSS
t
TDIS
t
TDIH
t
TDOV
t
TDOX
TDO
[+] Feedback