CY7C1298H
Document #: 38-05665 Rev. *B Page 9 of 16
Capacitance
[9]
Parameter Description Test Conditions
100 TQFP
Max. Unit
C
IN
Input Capacitance T
A
= 25°C, f = 1 MHz,
V
DD
= 3.3V
V
DDQ
= 2.5V
5pF
C
CLK
Clock Input Capacitance 5 pF
C
I/O
Input/Output Capacitance 5 pF
Thermal Characteristics
[9]
Parameter Description Test Conditions
100 TQFP
Package Unit
Θ
JA
Thermal Resistance
(Junction to Ambient)
Test conditions follow standard test
methods and procedures for measuring
thermal impedance, per EIA/JESD51
30.32 °C/W
Θ
JC
Thermal Resistance
(Junction to case)
6.85 °C/W
AC Test Loads and Waveforms
Note:
9. Tested initially and after any design or process change that may affect these parameters.
OUTPUT
R = 317Ω
R = 351Ω
5pF
INCLUDING
JIG AND
SCOPE
(a) (b)
OUTPUT
R
L
= 50Ω
Z
0
= 50Ω
V
T
= 1.5V
3.3V
ALL INPUT PULSES
V
DDQ
GND
90%
10%
90%
10%
≤ 1 ns
≤ 1 ns
(c)
OUTPUT
R = 1667Ω
R =1538Ω
5pF
INCLUDING
JIG AND
SCOPE
(a) (b)
OUTPUT
R
L
= 50Ω
Z
0
= 50Ω
V
T
= 1.25V
2.5V
ALL INPUT PULSES
V
DDQ
GND
90%
10%
90%
10%
≤ 1 ns
≤
1 ns
(c)
3.3V I/O Test Load
2.5V I/O Test Load
[+] Feedback