CY8C24123
CY8C24223, CY8C24423
Document Number: 38-12011 Rev. *G Page 25 of 43
DC Analog PSoC Block Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40
°C ≤ T
A
≤ 85°C, or 3.0V to 3.6V and -40°C ≤ T
A
≤ 85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only or unless otherwise specified.
DC POR and LVD Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40
°C ≤ T
A
≤ 85°C, or 3.0V to 3.6V and -40°C ≤ T
A
≤ 85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only or unless otherwise specified.
Note The bits PORLEV and VM in the following table refer to bits in the VLT_CR register. See the
PSoC Programmable
System-on-Chip Technical Reference Manual
for more information on the VLT_CR register.
Table 22. DC Analog PSoC Block Specifications
Symbol Description Min Typ Max Units
R
CT
Resistor Unit Value (Continuous Time) – 12.24 – kΩ
C
SC
Capacitor Unit Value (Switch Cap) – 80 – fF
Table 23. DC POR and LVD Specifications
Symbol Description Min Typ Max Units
V
PPOR0R
V
PPOR1R
V
PPOR2R
Vdd Value for PPOR Trip (positive ramp)
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
–
2.908
4.394
4.548
–
V
V
V
V
PPOR0
V
PPOR1
V
PPOR2
Vdd Value for PPOR Trip (negative ramp)
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
–
2.816
4.394
4.548
–
V
V
V
V
PH0
V
PH1
V
PH2
PPOR Hysteresis
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
–
–
–
92
0
0
–
–
–
mV
mV
mV
V
LVD0
V
LVD1
V
LVD2
V
LVD3
V
LVD4
V
LVD5
V
LVD6
V
LVD7
Vdd Value for LVD Trip
VM[2:0] = 000b
VM[2:0] = 001b
VM[2:0] = 010b
VM[2:0] = 011b
VM[2:0] = 100b
VM[2:0] = 101b
VM[2:0] = 110b
VM[2:0] = 111b
2.863
2.963
3.070
3.920
4.393
4.550
4.632
4.718
2.921
3.023
3.133
4.00
4.483
4.643
4.727
4.814
2.979
a
3.083
3.196
4.080
4.573
4.736
b
4.822
4.910
a. Always greater than 50 mV above PPOR (PORLEV = 00) for falling supply.
b. Always greater than 50 mV above PPOR (PORLEV = 10) for falling supply.
V
V
V
V
V
V
V
V
V
V
PUMP0
V
PUMP1
V
PUMP2
V
PUMP3
V
PUMP4
V
PUMP5
V
PUMP6
V
PUMP7
Vdd Value for PUMP Trip
VM[2:0] = 000b
VM[2:0] = 001b
VM[2:0] = 010b
VM[2:0] = 011b
VM[2:0] = 100b
VM[2:0] = 101b
VM[2:0] = 110b
VM[2:0] = 111b
2.963
3.033
3.185
4.110
4.550
4.632
4.719
4.900
3.023
3.095
3.250
4.194
4.643
4.727
4.815
5.000
3.083
3.157
3.315
4.278
4.736
4.822
4.911
5.100
V
V
V
V
V
V
V
V
V
[+] Feedback