Datalogic Scanning 1000I Barcode Reader User Manual


 
Interface Related Features
3-26 Magellan
®
1000i
Wand Emulation
Supported Symbologies
The Wand Emulation interface will transmit barcode data as a wand device would. This inter-
face will transmit the following barcode symbologies:
•UPC/EAN
UPC/EAN with addons
•Code 39
Full ASCII Code 39
Interleaved 2 of 5
•Codabar
•Code 128
Pharmacode 39 is transmitted as Code 39. All other barcode symbology types read by the scan-
ner will be transmitted as Code 128.
Wand Emulation Barcode Format
The following format settings are required for the wand emulation interface. These settings have
been pre-configured at the factory for Wand Emulation scanners.
UPC-A barcodes must include all 12 digits.
UPC-E barcodes must contain 8 digits, including a system digit, 6 data digits, and the
check digit.
EAN-13 barcodes must have all 13 digits.
EAN-8 barcodes must include all 8 digits.
Code 39, Code 39 Full ASCII, and Pharmacode 39 barcodes must NOT contain start /
stop characters.
Codabar barcodes must include the start / stop characters, presented in the ABCD format.
Interleaved 2 of 5 barcodes must have an even number of digits.