Datalogic Scanning 3200VSI Scanner User Manual


 
2D Symbologies
152
Magellan
TM
3200VSi
Composite Labels
Disable/Enable GS1 DataBar Omnidirectional 2D Component
When enabled, if a GS1 DataBar Omnidirectional label is decoded which has the 2D linkage
flag set, the 2D component must also be decoded or the base label will be discarded.
When disabled, only the GS1 DataBar Omnidirectional base label will be decoded and trans-
mitted regardless of the state of the linkage flag.
Disable/Enable GS1 DataBar Expanded 2D Component
When enabled, if a GS1 DataBar Expanded label is decoded which has the 2D linkage flag set,
the 2D component must also be decoded or the base label will be discarded.
When disabled, only the GS1 DataBar Expanded base label will be decoded and transmitted
regardless of the state of the linkage flag.
START / END
PROGRAMMING bar codes
Disable GS1 DataBar Omnidirectional 2D Component
DEFAULT
Enable GS1 DataBar Omnidirectional 2D Component
START / END
PROGRAMMING bar codes
Disable GS1 DataBar Expanded 2D Component
DEFAULT
Enable GS1 DataBar Expanded 2D Component