Datalogic Scanning D8330 Barcode Reader User Manual


 
REFERENCES
163
5.10 DISPLAY PARAMETERS (SOME M8300 MODELS ONLY)
5.10.1 Display Mode
The user can control the reader display behavior according to the following
selections:
Normal mode: When a barcode is read with the reader:
The code is sent to the Host.
The reader display is not cleared
. Therefore if any previous data was displayed
on the reader screen it remains.
There is no Local Echo to the reader display.
Clear Display After Decode mode: When a barcode is read with the reader:
The code is sent to the Host.
The reader display is cleared
. Therefore if any previous data was displayed on
the reader screen it is cancelled and the screen remains blank.
There is no Local Echo of the code to the reader display.
Local Echo mode: When a barcode is read with the reader:
The code is sent to the Host.
The reader display is cleared
.
The code is also sent to the reader display (Local Echo).
The cursor is positioned after the last printed character on the reader display.
Host messages sent to the reader
are always written to the reader display.