2.9 POWERSCAN
®
M8300 BATTERY MAINTENANCE
2.9.1 Battery Charging
Once the system is connected and powered, you can place the PowerScan
®
M8300
into the cradle to charge the battery.
When the reader is correctly inserted in the cradle, the "Reader" red LED on the cradle
goes on to indicate that the battery is charging. The "Reader" green LED on the cradle
goes on when the battery is completely charged.
2.9.2 Replacing PowerScan
®
M8300 Batteries
To change the batteries in your PowerScan
®
M8300 scanner, press the black button
or unscrew the fixing screw on the handle cover and extract the battery pack from the
reader handle.
NOTE
When the batteries are extracted from the scanner, the timer
maintains the current hour and date for about 1 minute.
Replace the old battery pack with a new one by inserting it within the reader handle
and pushing it until it clicks.
WARNING
Do not incinerate, disassemble, short terminals or expose to
high temperature. Risk of fire, explosion. Use specified
charger only. Risk of explosion if the battery is replaced by
an incorrect type. Dispose of the batteries as required by the
relevant laws in force.