HOST CONFIGURATION STRINGS
191
POWER SAVE
DESCRIPTION STRING
Sleep State disable BQ0
(only for D8330 series)
enable BQ1
Enter Sleep Timeout (100 ms) BR00-BR99
READING PARAMETERS
DESCRIPTION STRING
Trigger Type software trigger BK0
hardware trigger BK1
always on BK3
Trigger Signal trigger active level BA0
trigger active pulse BA1
Trigger Click disable Bc0
enable Bc1
Trigger-off Timeout (s) BD00 - BD99
FLASH ON (100 ms) BB001 - BB099
FLASH OFF (100 ms) BB101 - BB199
Reads per Cycle one read BC0
multiple reads BC1
Safety Time (100 ms) BE00 - BE99
Beeper Intensity very low intensity BG0
low intensity BG1
medium intensity BG2
high intensity BG3
Beeper Tone tone 1 BH0
tone 2 BH1
tone 3 BH2
tone 4 BH3
Beeper Type monotone BJ0
bitonal BJ1
Beeper Length long BI0
short BI1
Good Read Spot Duration disable BV0
short BV1
medium BV2
long BV3
Aiming System disabled Bj0
enabled Bj1
Cradle Beeper Intensity disable JI0
low intensity JI1
medium intensity JI2
high intensity JI3