Datalogic Scanning M8300 Barcode Reader User Manual


 
POWERSCAN
®
D8330/M8300
166
5.14 CONFIGURATION COPYING COMMANDS
5.14.1 Copy PowerScan D8330 Series
Procedure:
c
Connect the master (correctly configured reader) and the slave (reader to be
configured) together through two RS-232 serial interface cables and external
power supply. Accessory cables and power supply are available from your
Datalogic distributor to provide this connection.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG5
d
Using the slave reader, read the Restore Default barcode and then the RS-232
interface barcode from chapter 4 of this manual or from the Quick Reference
Guide.
e
With the master reader, read the Configuration Copy barcode below.
Copy Configuration
Ì$+ZZ0$-*Î
The configuration will be copied from the master to the slave reader. The slave
reader signals the end of the procedure with a series of beeps.
Note: The master reader can be configured for any interface.