Datalogic Scanning QS6500 Barcode Reader User Manual


 
Product Reference Guide 2-1
Chapter 2
Bluetooth Models
The following features and descriptions apply only to Bluetooth (BT)
models of the imager.
Linking an Imager with a Base
Station
Follow these instructions to link the two devices:
1. Connect power to the Base Station. The radio LED (marked with
an antenna symbol) will blink amber and the Base Station will
beep.
2. To ensure the Base Station is unlinked from any other imagers,
press the button located on its bottom side for three seconds.
3. Place the imager in the Base Station for one minute to get a small
charge in the battery.
4. Read the label on the Base Station with the imager. The imager
will sound a good read beep and the LED will flash amber.
5. Replace the imager in the Base Station to continue the charge.
Once an imager is linked to a Base Station, they will remain linked until
specific action is taken to unlink them (see
Unlinking). They will remain
linked if the Base Station is unplugged, if the battery is removed from
the imager or if the entire charge is used up, and if the imager is taken
out of range of the Base Station. Under normal operation, scanning of
the link label will only be required once in the life of the product.