Datamax E-4203 Printer User Manual


 
26 E-4203/E-4204/E-4304
4.4.3 Step by Step Modification of the Printer Setup
The following is an example of Printer Setup modification. Although this
example will detail how to modify the serial Baud Rate, the same method
can be used to change any of the printer’s menu item settings.
; Note: It is recommended that the Printer Setup Mode not be entered while in
Peel Mode or with the optional Present Sensor enabled. Depending on
label size this can cause unpredictable results.
1. With printer ‘Off’ and properly loaded with media, press and hold the
button while powering ‘On’ the printer. Continue to hold the
button until the PAUSED Light turns off, then release it.
2. Press and hold the
button and count 7 flashes of the FAULT Light,
then release it. The following printout should be produced:
3. Press the button one time to increment to the 19200 bps value.
The following printout should be produced:
4. At this point you will accept the current values for “test” and exit the
Printer Setup Procedure by simultaneously and briefly pressing the
+
buttons. Wait until the PAUSED Light goes off.
; Note: If you wish to discard your changes and revert back to the
previous values simply turn off power to the printer before Step 5.
5. Now you can save your changes and resume by
simultaneously and briefly pressing the
+
buttons. Wait until the
PAUSED Light goes off.