Datamax SV-3306 Printer User Manual


 
20 ST/SV-3210 and ST/SV-3306
3.6 Resetting the Printer
There are two different reset levels possible for the printer:
3.6.1 Warm Reset
To reset the printer and return to the on-line mode: Press the PAUSE
button to go off-line and then press the F1 + F3 buttons simultaneously.
3.6.2 Factory Default Reset
To return the printer to default database settings (see the table below),
perform the following procedure.
Œ Turn the printer ‘Off’.
Press and hold the PAUSE/F1, FEED/F2 and TEST/F3 buttons while
turning ‘On’ the printer.
Ž After the Fault Indicator flashes (approximately 20 seconds), release
all three buttons.
For verification, a Configuration Ticket can be printed. The printout will
reflect default settings until new configuration data is sent to the printer.
Default Database Settings
Function ST/SV 3210 Values ST/SV 3306 Values
Memory Configuration:
[1]
Internal Module
Scalable Fonts
128
64
128
64
Character Set:
(DPL parser mode only)
Standard Standard
Cutter Auto Detect Auto Detect
Parser Mode:
[2]
DTPL DTPL
Print Speed:
[3]
8 4
Slew Speed:
[3]
8 4
Backup Speed:
[3]
3 3
Stock ID 5 5
Print Width 1.89 inches (48 mm) 1.92 inches (49 mm)
[1]
Memory allocations are represented in 4KB units each and modifiable only when in the
DPL parser mode.
[2]
The parser mode setting may arrive factory-configured to meet your application;
otherwise see Section 4.3.1.
[3]
All speed values given in Inches Per Second.