Dell 1550 Server User Manual


 
Version 0.3, 4 December, 2000 DCSE: PowerEdge 1550 Self-Study
Dell Page 81
Message Problem Suggested Solution
Configuration of
NVRAM and drives
mismatch. Run
View/Add Configuration
option of PERC 3/DC
WebBIOS Configuration
Utility.
Press any key to run
the Configuration Utility.
The configuration
stored in the PERC
3/DC adapter does
not match the
configuration stored in
the drives.
Press <Ctrl>+<H> to enter the PERC
WebBIOS Configuration Utility. Choose
View/Add Configuration from the
Configure menu. Choose View/Add
Configuration to examine either the
configuration in NVRAM or the
configuration stored on the disk drives.
Resolve the problem by selecting one of
the configurations.
Unresolved
configuration mismatch
between disks and
NVRAM on the adapter
after creating a new
configuration
Some legacy
configurations in the
drives cannot be
cleared.
Clear the configuration.
Low level format the related drives and re-
create the configuration.
1 Logical Drive Failed A logical drive failed to
sign on.
Make sure all physical drives are properly
connected and are powered on. Press
Ctrl>+<H> to enter the PERC WebBIOS
Configuration Utility to find out if any
physical drives are not responding.
Reconnect, replace, or rebuild any drive
that is not responding.
X Logical Drives
Degraded
x number of logical
drives signed on in a
degraded state.
Make sure all physical drives are properly
connected and are powered on. Press
Ctrl>+<H> to enter the PERC WebBIOS
Configuration Utility to find if any physical
drives are not responding. Reconnect,
replace, or rebuild a drive that is not
responding.
1 Logical Drive
Degraded
A logical drive signed
on in a degraded
state.
Make sure all physical drives are properly
connected and are powered on. Press
<Ctrl> <H> to enter the PERC WebBIOS
Configuration Utility to find out if any
physical drives are not responding.
Reconnect, replace, or rebuild any drive
that is not responding.
Insufficient memory to
run BIOS. Press any
key to continue…
Not enough PERC
3/DC memory to run
PERC 3/DC BIOS.
Make sure PERC 3/DC cache memory
has been properly installed.
Insufficient Memory Not enough memory
on the PERC 3/DC
adapter to support the
current configuration.
Make sure PERC 3/DC cache memory
has been properly installed.