Menu item Description
Device-Initiated E-mail
None
Use Device SMTP Credentials
Device Userid
Device Password
Kerberos 5 Realm
NTLM Domain
Specifies what credentials will be used when communicating to the
SMTP server. Some SMTP servers require credentials in order to send e-
mail.
Notes:
None is the factory default setting for Device-Initiated E-mail.
Device Userid and Device Password are used to log in to the SMTP
server when "Use Device SMTP Credentials" is selected.
Security menu
Miscellaneous menu
Menu item Description
Panel Logins
Login failures
Failure time frame
Lockout time
Login timeout
Limits the number and time frames of failed login attempts from the printer control
panel before all users are locked out
Notes:
“Login failures” specifies the number of failed login attempts before users are
locked out. Settings range from 1–50. 3 attempts is the factory default setting.
Failure time frame” specifies the time frame during which failed login attempts
can be made before users are locked out. Settings range from 1–60 minutes. 5
minutes is the factory default setting.
“Lockout time” specifies how long users are locked out after exceeding the
login failures limit. Settings range from 0–60 minutes. 5 minutes is the factory
default setting. 0 indicates the printer does not impose a lockout time.
Login timeout” specifies how long the printer remains idle on the Home screen
before automatically logging the user off. Settings range from 1–900 seconds.
300 seconds is the factory default setting.
Remote Logins
Login failures
Failure time frame
Lockout time
Login timeout
Limits the number and time frames of failed login attempts from a computer before
all remote users are locked out
Notes:
“Login failures” specifies the number of failed login attempts before users are
locked out. Settings range from 1–50. 3 attempts is the factory default setting.
Failure time frame” specifies the time frame during which failed login attempts
can be made before users are locked out. Settings range from 1–60 minutes. 5
minutes is the factory default setting.
Lockout time” specifies how long a user is locked out after exceeding the login
failures limit. Settings range from 0–60 minutes. 5 minutes is the factory default
setting. 0 indicates the printer does not impose a lockout time.
“Login timeout” specifies how long the remote interface remains idle before
automatically logging the user off. Settings range from 1–900 seconds. 300
seconds is the factory default setting.
Understanding printer menus
119