Information Update 7
Table 1-3. LCD Status Messages
Line 1
Message
Line 2
Message
Causes Corrective Actions
SYSTEM
ID
SYSTEM NAME SYSTEM ID is a unique name,
five characters or less, defined by
the user.
SYSTEM NAME is a unique
name, 16 characters or less,
defined by the user.
The system ID and name display
under the following conditions:
• The system is powered on.
• The power is off and active
POST errors are displayed.
This message is for information
only.
You can change the system ID
and name in the System Setup
program. See your User's Guide
for instructions.
E0000 OVRFLW CHECK LOG LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
Check the SEL for details on the
events.
E1000 FAIL SAFE Failsafe event. Capture the event log and see
"Getting Help" in your
Installation and Troubleshooting
Guide.
E1000 MISCONFIG Missing or improperly installed
VRMs.
See "Installing a Processor VRM"
in your Installation
and Troubleshooting Guide. If
the VRMs appear to be properly
configured and installed, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
E0119 TEMP AMBIENT Ambient system temperature
is out of acceptable range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0119 TEMP PROC # The specified processor is out
of acceptable temperature range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.