Dell C5220 Server User Manual


 
14
Table 1-5. Blinking Fault LED Conditions
ID LED Blue Off Normal status (by IPMI
Chassis Identify
command or System ID
Button)
Turn off the ID LED.
1. ipmitool raw 0x00 0x04
0x00
2. ipmitool raw 0x00 0x04
0x00 0x00
Solid On Identify the system Turn on the ID LED.
1.ipmitool raw 0x00 0x04 0x3c
01
Blinking Identify the system with
interval
1. IPMI chassis identify
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60 sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)
Heartbeat
LED
Green Off BMC is not ready
Blinking BMC is ready
Index Sensor Name Event Triggers
1 CPU Temp
Upper Critical Going High
Upper Non-Critical Going High
Ambient Temp,
DIMM Temp
Rear Temp 1
Rear Temp 2
Rear Temp 3
2 SLED 12V
Upper Critical Going High
Upper Non-Critical Going High
Table 1-4. LED Status
LED Color Status Occurrence Note