116 Troubleshooting
Foreign Configuration Not Found in <Ctrl><R> Error Message
Error Message: The foreign configuration message is
present during POST but no foreign configurations are
present in the foreign view page in CTRL+R. All
virtual disks are in an optimal state.
Corrective Action: Ensure all your PDs are present and all VDs are in optimal
state. Clear the foreign configuration using <Ctrl><R> or Dell
OpenManage Server Administrator Storage Management.
CAUTION: The physical disk goes to Ready state when you clear the foreign
configuration.
If you insert a physical disk that was previously a member of a virtual disk in
the system, and that disk’s previous location has been taken by a replacement
disk through a rebuild, you must manually remove the foreign configuration
flag of the newly inserted disk.
Previous Configuration Cleared or Missing Error Message
Error Message: Previous configuration(s) cleared or
missing. Importing configuration created on XX/XX
XX.XX. Press any key to continue, or ’C’ to load the
configuration utility.
Probable Cause: The message indicates that the controller and physical disks
have different configurations.
Corrective Action: You can use the BIOS Configuration Utility
(<Ctrl><R>) to clear the foreign configuration.
Invalid SAS Topology Detected Error Message
Error Message: Invalid SAS topology detected. Please check
your cable configurations, repair the problem, and
restart your system.
Probable Cause: The SAS cables for your system are improperly connected.
Corrective Action: Check the cable connections and fix problems if any.
Restart the system.