Draper Video Projector Projector User Manual


 
220 V Revelation by DRAPER Page 8 of 8
The VIC 12 KIT includes all the components necessary for the VIC 12 to work
with the Revelation. Follow these steps to install the components in this KIT.
Close the door to the Revelation.
DISCONNECT POWER TO THE REVELATION.
Remove the covers from the electrical enclosure.
Attach the pre-wired limit switch [1] to the shaft mounting bracket which
is closest to the motor as shown in FIGURE #1. Using the
#6–32 x 1" [2] long screws and #6 lock washers [2] provided.
Run the wires through the open grommet in the end of the electrical
enclosure that is toward the motor as shown in FIGURE #1 and connect
them as fol lows:
Connect the black wire to screw #1 of TB2
Connect the blue wire to screw #2 of TB2. (Be sure that wires do not
interfere with moving linkage or the sliding inner pan)
Put the 12V ACTIVATOR LEVER [3] onto the shaft as shown in Figure
#2. The 12V ACTUATOR LEVER will need to be spread out before it will
fi t onto the shaft. The door to the Revelation must be closed before going
on to step #7
Position the 12V ACTUATOR LEVER by rotating it into the limit switch
until the limit switch clicks and secure the lever onto the shaft using the
#10-32 screw [4] and lock washer [5] supplied with the lever. (Be sure
that the screw on the lever is tightened so that the lever does not twist on
the shaft.)
After the VIC 12 [7] is installed with the screen, run the wiring to the
Revelation using the cord strain relief [6] and connect to TB1 as shown
in the Rev e la tion wiring diagram.
Put the covers back on to the electrical enclosure.
Reconnect power to the revelation.
VIC12 Kit Installation Instructions
FIGURE #1
FIGURE #2
VIC 12 OR VIC 12 MODIFIED INSTALLATION PART LIST
ITEM # DESCRIPTION QTY
1 PRE-WIRED LIMIT SWITCH 1
2 SCREW #6–32 X 1"(25.4mm) LONG 2
PHIL PAN HD W/ EXT LOCK WASHER
3 12v ACTUATOR LEVER 1
4 SCREW #10–32 X 3/8" (9.525mm) LONG SHCS 1
5 WASHER #10–.190" I.D. X .375" (9.525mm) O.D. 1
ZINC INTERNAL TOOTH
6 FITTING CORD CRIMP STRAIN RELIEF 1
7 VIC 12 OR VIC 12 MODIFIED 1
TOOLS NEEDED
MED POINT PHILLIP SCREW DRIVER
I
/8" FLAT BLADE SCREW DRIVER
3
/16" ALLEN WRENCH
Pre-wired limit switch
Motor
12V Actuator lever
CR 1
CR 2
C 1
TB 2
Blue
Black
12345678910
Rotate lever
until the limit
switch clicks.
Tighten lever
onto shaft.
12V actuator lever
Pre-wired
limit switch
www.draperinc.com
(765) 987-799
9