Enterasys Networks 9E312-12 Switch User Manual


 
Operation
3-4
and control the SMB LANVIEW diagnostic LEDs. Although the system diagnostic
controller and the main host processor can operate independently of each other if
needed, they exchange information about each others status and overall module
condition. The information gathered by the diagnostic controller is available to
the network manager via local/remote management and the LCD located on the
environment module. The 9E312-12 is designed to continue functioning in the
event of a diagnostic controller fault.
DC/DC Converter
The DC/DC converter converts the 48 VDC on the system power bus to the
necessary operating voltages for its host network services module. The diagnostic
controller monitors and controls the operation of the DC/DC converter.
INB Interface
The INB Backplane is designed to transport fixed length data blocks between
modules in the MMAC-Plus using a Time Division Multiplexing (TDM) design.
The MMAC-Plus INB bus delivers 2.0 Gbs of true data bandwidth with all control
and management communication being serviced on the 8 bit out-of-band bus. The
INB can time slice its bandwidth using one of three methods. The default method
is standard TDM round-robin bandwidth arbitration, the second method is for
modules to reserve a specific amount of bandwidth using MONARCH,
Cabletron’s INB Bandwidth Arbitrator, the third method permits the lowest slot
number to use any bandwidth not used by the previous two methods.