Enterasys Networks C2RPS-CHAS2 Power Supply User Manual


 
Connecting the PSM Cables and AC Power Cords
2-6 Installation
Connecting the PSM Cables and ACPower Cords
ThePSMsareconnectedtotheSecureStackC2EthernetswitchdevicesusingC2RPSPSM
Cables.
ToconnectthePSMs,proceedasfollows:
1. ConnectoneendoftheC2RPSPSMCable(showninFigure 23)totheRedundant
PowerSupplyconnectorontheswitch device.Thenconnecttheotherendtothe
RedundantPowerSupplyconnectorattherearofthePSMasshowninFigure 24and
Figure 25.
2. ConnectastandardACpowercordtotheACinputpowerconnectoronthePSM
showninFigure 24,thenplugtheACpowercordintothemainACpoweroutlet.
3. The
greenPowerLEDonthefrontofthePSMwillilluminatetoindicateasuccessful
connection.IftheLEDremainsoff,proceedasfollows:
a. ChecktheACpowercordconnectionattheACpowersourceandmakesurethe
powersourceiswithinspecification.
b. Checkthe ACpowerconnectiontothe
PSM.
c. SwaptheACpowercordwithaknown goodone.
d. IfthegreenLEDcontinuestoremainoff,contactEnterasysNetworks.Referto
GettingHelponpage 15forinstructions.Otherwise,proceedtostep4.
4. IfinstallingtwoPSMpowersupplies,repeatsteps1through3forthesecondPSM.
Figure 2-3 C2RPS-PSM Cable
Figure 2-4 Power Connectors on C2RPS-PSM(rear view)
1 Redundant Power Supply connector 2 AC power connector (rear of chassis)
AC LINE
100-240 VAC
50-60 Hz
2A MAX
Redundant Power Supply
À Á