Enterasys Networks 6H308-48 Switch User Manual


 
Using LANVIEW
Matrix DFE-Gold Series PoE Module 4H4285-49 Installation Guide 4-3
Viewing the PoE Port Status
Ifthe4H428549isinstalledinanN5chassisorisreceiving48Vdcfromanexternal
NPOEPowerSystemtosupportconnectionstoPDs(PoweredDevices),youcanviewthe
powerstatusindicationsontheRXandTXLEDs.However,onlyonegroupof12ports
maybe
viewedatatime.ToviewthePoEportstatus,refertoFigure 41andproceed as
follows:
1. PresstheGROUPSELECTbuttonformorethentwosecond.The4H428549willenter
thePoEportstatusmodeandthePoELEDturnsgreen.
2. Now,everytimeyoupresstheGROUP
SELECTbuttonforlessthanasecond,the
GROUPLEDlightsupinsequence,indicatingwhichGroupisselected.ThePoE
POWERSTATUSforthatgroupofsegmentsisthenindicatedbytheRXandTXLEDs
foreachsegment.Ifthereispowerattheport,theRXLEDis
greenandtheTXLEDis
off.Otherwise,refertoTable 41fortroubleshootinginformation.
3. PresstheGROUPSELECTbuttonagainformorethantwosecond.Thisreturnsthe
4H428549tothedefaultstatusmodetomonitorRX(receive)andTX(transmit)
activityandthePoELEDturnsoff.
Table 4
1describestheLEDindicationsandprovidesrecommendedactionsas
appropriate.
Note: The terms flashing, blinking, solid, and Alternately used in Table 4-1 indicate
the following:
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid indicates a steady LED light. No pulsing.
Alternately indicates an LED is flashing at a steady rate other than 50% on, 50% off.
Table 4-1 LANVIEW LEDs
LED Color State Recommended Action
MGMT Off Off. This module is NOT the
Management Module.
None.
Green Solid. This module is the
designated Management
Module.
None.
Amber Flashing. This is a
temporary indication that the
module is saving data.
None.