Epson ELPMBPJF Projector Accessories User Manual


 
ISSUED: 01-23-07 SHEET #:055-9498-1
Visit the Peerless Web Site at www.peerlessmounts.com
6 of 10
For Technical Support Contact Peerless Mounts at 1-800-729-0307 or 708-865-8870.
NOTE: ACC203 (Alligator
concrete anchors are not
included) are recommended.
Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach ceiling plate (G) using two concrete
anchors and #14 x 2.5" wood screws (F) as shown in
Illustration A and 1, 2 and 3. Tighten all fasteners.
IMPORTANT: It is the responsibility of the installer to
verify that the ceiling will safely support the
combined load of all attached hardware and
components.
Skip to step 2.
Installation to Concrete Ceilings
FOR DIRECT ATTACHMENT TO LOAD BEARING
CONCRETE ONLY! Concrete expansion anchors are
not intended for attachment to concrete ceilings
covered with a layer of plaster, drywall, or other
finishing material. If mounting to concrete ceiling
covered with plaster / drywall is unavoidable, plaster /
drywall must be counterbored as shown below.
WARNING
When installing Peerless mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete surface in
the 1/4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must meet ASTM
C-90 specifications.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
Never exceed the Maximum UL Load Capacity of 50 lb (22.7 kg).
WARNING
1
CUTAWAY VIEW
INCORRECT
concrete
metal
bracket
plaster/
dry wall
CORRECT
concrete
metal
bracket
plaster/
dry wall
Illustration A
F
G
CONCRETE CEILING
CONCRETE
ANCHOR
Tighten wood screws so that wall plate is firmly
attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.
Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
Drill holes and insert anchors
Place ceiling plate over anchors and secure with screws
Tighten all fasteners
concrete
surface
1
3
2
G
F
concrete
anchor
concrete
anchor