DM-D110/D210 User’s Manual 5
English
Precautions when Installing
❏ Ensure that the power switches of the customer display and the device that it
is connected to are turned off before connecting the cable.
❏ The RS-232 connector of the stand (DP-110/210) is fitted with inch screws
(hex nuts). Replace these with the included metric screws if you need metric
screws. The inch screws and metric screws can be distinguished by the
presence or lack of grooves (see Illustration H).
❏ Refer to the DM-D110 Technical Reference Guide or the DM-D210 Technical
Reference Guide for information on how to install the device.
Power Switch On/Off
Set the power switch on the base of the display unit to “|” to turn the power on
and execute the memory test. Nothing is displayed on the screen if the test finishes
normally. An error message is displayed if an error is detected.
Set the power switch to “O” to turn the power off.
Turn on the power to the customer display before turning on the power of the
computer, printer or other host devices.
Note:
If you are connecting to the USB model of the EPSON TM printer, always ensure that you
turn on the power to the customer display first. If you turn on the power to the customer
display too late, the system may not be able to detect the customer display.
Changing the Orientation of the Display Unit
The angle and direction of the display unit can be changed by pressing on the
struts with your hand while moving the display unit. The display unit will move
with only light pressure, so do not apply more pressure once the unit stops
moving. Applying excess force to move the display unit may cause damage.
When installed in the IR-700 or TM printer, there may be situations where the
display unit cannot be turned to the desired direction. In these situations, remove
the customer display and base unit, then adjust the position of the lug in the base
unit before reattaching.
The range of movement of the display unit is given in the following table. (DM-
D110: Illustration J, DM-D210: Illustration K)
DM-D110 DM-D210
Tilt Maximum Angle 48° (4 Steps,
5 Positions)
Maximum Angle 36° (3 Steps,
4 Positions)
Horizontal
Rotation
Maximum Angle 90° (45° Left or Right) Maximum Angle 330°