Epson MF1436-02 Computer Hardware User Manual


 
6 EPSON S5U1C63000H2 MANUAL
(S1C63 FAMILY IN-CIRCUIT EMULATOR)
CHAPTER 2: S5U1C63000H2 PACKAGE
2.5 Setting the Dip Switch
The S5U1C63000H2 works with a personal computer that runs Windows as a host. With a general
computer that meets the condition, the serial transfer rate set at the factory (9600 bps) is good for use. In
case the rate is changed, the transfer rate between the host computer can be changed by this switch. The
switch also sets a self diagnostic function, which is equipped in the S5U1C63000H2, working or not
working at the power on. Figure 2.5.1 shows the dip switch.
— O P E N —
1
2345678
Fig. 2.5.1 Dip switch
<Setting baud rate>
SW1–3
OPEN
OPEN
OPEN
OPEN
OPEN
Other settings
SW4
OPEN
OPEN
ON
OPEN
ON
SW5
OPEN
ON
OPEN
OPEN
ON
SW6
OPEN
ON
ON
ON
OPEN
Baud rate setting
9600 bps, 8-bit character, 1 stop bit, no parity (factory setting)
2400 bps, 8-bit character, 1 stop bit, no parity
4800 bps, 8-bit character, 1 stop bit, no parity
19200 bps, 8-bit character, 1 stop bit, no parity
38400 bps, 8-bit character, 1 stop bit, no parity
Do not set.
Note: The setting at the host end is recommended to be "9600 bps, 8-bit character, 1 stop bit, no parity".
<Setting the self diagnostic function>
SW8
OPEN
ON
Setting
Self diagnosis On
Self diagnosis Off (factory setting)
Note: When the S5U1C63000H2 is started with the self diagnosis on, it takes approx. 5 minuets to be
ready for use.
Open means that the switch lever is at upper side.
On means that it is at lower side.