Adding an Additional Power Module
(CC 600 and CC 800)
Each additional power module occupies two (USA/domestic
models) or three (international models) of the cubby’s AAP
spaces, reducing the amount of AAP space available in the
cubby for cable pass through (split) or passive AAPs. Use the
following guidelines as applicable:
1
Replacement two-space, three-space, and four-space shelf
brackets and cable pass-through (split) AAPs are available
from Extron, and may be required to maximize the
remaining available space if you add a power module.
Cable Cubby 200 models — Adding a second power
module is not possible.
Cable Cubby 300 models — Adding a second power
module is not recommended. Depending on the
model, with a second power module, there is room
left for either only a single one-space AAP or no AAP
space left at all.
Cable Cubby 600 and 800 international models — In
general, you probably do not need replacement shelf
brackets when you add an international module to
an international Cable Cubby, because the power
module replaces a three-space shelf that is standard
in all international cubbies.
Figure 3-3 shows typical confi gurations before and after
you add a second power module to an international
Cable Cubby 600.
Before
Three AAP
Space Shelf
Two AAP
Space Shelf
Two AAP
Space Shelf
After
UNSWITCHED
230~50/60Hz
5A
UNSWITCHED
230~50/60Hz
5A
UNSWITCHED
230~50/60Hz
5A
Figure 3-3 — International Cable Cubby 600 with
second power module
Figure 3-4 shows typical confi gurations before and after
you add a second power module to an international
Cable Cubby 800.
Before
After
Four AAP
Space Shelf
Four AAP
Space Shelf
Three AAP
Space Shelf
UNSWITCHED
230~50/60Hz
5A
UNSWITCHED
230~50/60Hz
5A
UNSWITCHED
230~50/60Hz
5A
Figure 3-4 — International Cable Cubby 800 with