5. Execute a ping command by entering ping followed by a space and
the new IP address at the command prompt. For example:
ping 10.13.197.7
C:\>ping 10.13.197.7
Pinging 10.13.197.7 with 32 bytes of data:
Reply from 10.13.197.7: bytes=32 time<10ms TTL=128
Reply from 10.13.197.7: bytes=32 time<10ms TTL=128
Reply from 10.13.197.7: bytes=32 time<10ms TTL=128
Reply from 10.13.197.7: bytes=32 time<10ms TTL=128
Ping statistics for 10.13.197.7:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
NOTE: You can reconnect using either Telnet or a web browser
to verify that the update was successful.
6. After verifying that the IP address change was successful, enter and
issue the “arp –d” command at the DOS prompt. For example:
arp –d 10.13.197.7 removes 10.13.197.7 from the ARP table
or
arp –d* removes all static IP addresses from the ARP table.
Loading the Start-up Page
NOTES:
If your Ethernet connection to the matrix switcher is unstable,
try turning off the proxy server in your web browser. In Microsoft
Internet Explorer, click Tools > Internet Options >
Connections > LAN Settings, uncheck the Use a proxy
server... box, and then click OK.
For details on operating the switcher via HTML pages, see the
"HTML Operation" section in the DMS Series Matrix Switchers
User Guide.
1. Start the web browser program.
2. Click in the Address eld.
3. Enter the Matrix IP address in the Address eld.
NOTE: 192.168.254.254 is the factory-specified default value for
this field.
4. Press the keyboard <Enter> key. The switcher checks whether it is
password-protected.
If the switcher is not password-protected, it checks and
downloads the HTML start-up page. The switcher is ready for
operation via HTML remote control.
If the switcher is password-protected, it downloads the Enter
Network Password page.
NOTE: A User name entry is not required.
5. Enter the appropriate administrator or user password in the
Password eld and click OK.
The switcher downloads the HTML start-up page. The switcher is
ready for operation via HTML remote control.