TP Cable Termination and Recommendations
Figure 9 details the recommended termination of both ends of TP cables with RJ-45
connectors in accordance with the TIA/EIA-T568B wiring standard.
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA
T568-B
TP Wires
12345678
Pins:
Figure 9. TP Cable Termination
NOTE: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the transmitter and receiver. The DTP T HWP D and DTP T UWP D family
of transmitters do not work properly with these cables.
Supported cables
The DTP T HWP D and DTP T UWP D family of transmitters are compatible with shielded
twisted pair cables (F/UTP, SF/UTP, and S/FTP).
Cable recommendations
Extron recommends using the following practices to reduce transmission errors and achieve
full transmission distances up to 230 feet (70 m) on the 232 models or 330 feet (100 m) on
the 332 models.
Use the following Extron XTP DTP 24 SF/UTP cables and DTP 24 connectors for the
best performance:
XTP DTP 24/1000 Non-Plenum 1000’ (305 m) spool 22-236-03
XTP DTP 24P/1000 Plenum 1000’ (305 m) spool 22-235-03
XTP DTP 24 Plug Package of 10 101-005-02
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Use no more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are
required, use shielded couplers and punch down connectors.
NOTE: When using STP cable in bundles or conduits, consider the following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or Velcro
®
.
Separate twisted pair cables from AC power cables.