Extron electronic MAV Switch User Manual


 
CrossPoint / MAV Matrix Switchers • Remote Control
Remote Control, cont’d
4-6
CrossPoint / MAV Matrix Switchers • Remote Control
4-7
Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com. Refer also to the CrossPoint 450 Plus / MAV Plus User’s Manual at www.extron.com.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Audio output volume
Set the audio volume to a specific
value
X@*X%V OutX@•VolX%]
Example:
1*50v
Out01•Vol50
] Set output 1 volume to an X% value of 50, an
attenuation of 14 dB (79% of total volume).
Increment volume
X@+V OutX@•VolX%]
Increase volume by 1 step.
Example:
1+V
Out01•Vol51
]
Decrement volume
X@-V OutX@•VolX%]
Decrease volume by 1 step.
Read output volume
X@V X%]
Save and recall presets
N
• If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.
The following characters are invalid in preset names: + - , ` @ = [ ] { } ‘ “ ; : | \ and ?.
Save current configuration as a
global preset
X^,
SprX^]
Command character is a comma.
Example:
9
,
Spr09]
Save current ties as preset 9.
Recall a global preset
X^.
RprX^]
Command character is a period.
Example:
5
.
Rpr05]
Recall preset 5, which becomes the current
configuration.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Lock (executive) modes
N
See “Setting the front panel locks (Executive modes)” on page 3-4 for more information on the Lock modes.
Lock all front panel functions 1X
Exe1
]
Enable Lock mode 1.
Lock advanced front panel functions 2X
Exe2
]
Enable Lock mode 2.
Unlock all front panel functions 0X
Exe0
]
Enable Lock mode 0.
View lock status X
X&]
N
X& = Lock mode 0, 1, or 2
N
X@ = Output number 01 – (maximum number of outputs for your model)
X% = Volume 0 – 64 (1 dB/step except for 0-to-1, which is 22 dB) (default = 64 [0 dB])
X^ = Preset number 00 - 64 (00 = current configuration, for viewing only)