COMMAND DESCRIPTION
ss[BLANKoo]
Blanks a specific output.
Where
o oo = 01 16 for output
Volume Commands
These commands control volume levels for both inputs and outputs. You can adjust input volume
levels to minimize drastic changes in volume when performing switches. As with switching
commands, all "load" commands, identified by [L], require a [TAKE] command to execute
changes.
COMMAND DESCRIPTION
[MUTEoox]
Used to mute/un-mute a specific output and request
current status.
Where
o oo = 01 16 for output
o x = 0 to disable mute, 1 to enable mute
o x = ? to request current state
o x = (left blank) to toggle current state
[MUTE]
Toggle mute/un-mute all outputs
[MUTE?]
Queries all mutes.
[VOL+]
Increase volume for all outputs
[VOL-]
Decrease volume for all outputs
[VOL@]
Restores factory default to all outputs
[VOL?]
Queries all volume levels.
[VOLoox]
Increments/decrements volume level for a specific
output.
Where
o oo = 01 16 for output
o x = + (plus sign) to increment output
volume
o x = - (minus sign) to decrement output
volume
o x = @ to return output volume to factory
default
o x = ? to request current volume level
[VOLooxxx]
Sets volume level for a specific output in dB. The range
is -55.0 dB - +9.0 dB.
Where
o oo = 01 16 for output
o xxx = -550 to 90
Note: Level is set in .5 dB steps. For example, -23.5 dB