Extron electronic MSX1616HR Switch User Manual


 
32
MSX1616 OPERATION MANUAL - v1.0 5/8/02 2002 - INLINE, INC.
COMMAND DESCRIPTION
[VINiix]
Increments/decrements input volume level for a specific
input.
Where
o ii = 01 16 for input
o x = + (plus sign) to increment input
volume
o x = - (minus sign) to decrement input
volume
o x = @ to return input volume to factory
default (0 dB)
o x = ? to request current volume level
[VINiixxx]
Increments/decrements input volume level for a specific
input.
Where
o oo = 01 16 for input
o xxx = -640 - 0
Note: 0 equals max (+0.0 db), -640 equals minimum
(-55.0 dB)
[LMUTE,a,b,c,d,e,f,g,h,I,j,k,l,m,n
,o,p,]
Preload mute state for all outputs.
Must send a [TAKE] command to execute changes.
Where
o a = 0 to disable, 1 to enable for output 1
o b = 0 to disable, 1 to enable for output 2
o c = 0 to disable, 1 to enable for output 3
o d = 0 to disable, 1 to enable for output 4
o e = 0 to disable, 1 to enable for output 5
o f = 0 to disable, 1 to enable for output 6
o g = 0 to disable, 1 to enable for output 7
o h = 0 to disable, 1 to enable for output 8
o etc.
[LMUTE,?]
Queries all LMUTE commands.
[LVOL,aaa,bbb,ccc,ddd,ee,efff,gg
g,hhh,iii,jjj,kk,lll,mmm,nnn,ooo,p
pp]
Preload output volume level for all outputs.
Must send a [TAKE] command to execute changes.
Where
o aaa = -550 to 90 for output 1
o bbb = -550 to 90 for output 2
o ccc = -550 to 90 for output 3
o ddd = -550 to 90 for output 4
o eee = -550 to 90 for output 5
o fff = -550 to 90 for output 6
o ggg = -550 to 90 for output 7
o hhh = -550 to 90 for output 8
o etc.
Note: Level is set in .5 dB steps. For example, 23.5dB
is entered as -235
[LVOL,?]
Queries any previously loaded LVOL commands.