Extron electronic MTP DA8 Switch User Manual


 
VersaTools
®
MTP DA4 and MTP DA8 • InstallationVersaTools
®
MTP DA4 and MTP DA8 • TP Cable Advantages
VersaTools
®
MTP DA4 and MTP DA8, cont’d
4. Attach the rack shelf to the rack using the supplied bolts.
Only products in the VersaTools line can be mounted on
a VersaTools shelf. Most 1U rack-mountable Extron
products can be mounted on the standard shelf.
Use 2 mounting holes on
opposite corners.
1/2 Rack Width False Front
Face Plate
(2) 4-40 x 3/16" screws
6" Deep Rack Shelf
M
TP
DA
SE
RIES
Figure 3 — Mounting on a 6" deep rack shelf
Use 2 mounting holes on
opposite corners
(2) 4-40 x 3/16" screws
False Front Panel
(uses 2 screws)
1U Universal
Rack Shelf
MTP DA SE
RIES
Figure 4 — Mounting on a 1U universal rack shelf
4. Enable or disable audio or serial distribution mute — If
desired, locate jumper J9 on the main board and shift the
jumper from the disable mute (S) (front) to the enable
mute (A) (rear) position (figure 2).
When J9 is set to the disable mute (S) (front) position,
the video mute has no affect on the DA’s audio or serial
distribution.
When J9 is set to the enable mute (A) (rear) position, the
DA mutes the audio or serial output when its contact
closure video mute is activated.
5. Replace the top cover.
6. Reinstall the six screws removed in step 2. If any
mounting brackets were removed in step 1, put them back
into position as you reinstall the screws.
7. If applicable, reinstall the DA and reconnect all cables.
Installation
CAUTION
Installation and service must be performed by
authorized personnel only.
The 1U high, half rack width MTP DA can be set on a table,
mounted on a rack shelf, mounted to a rack without a shelf, or
mounted under a desk or tabletop.
Tabletop use
Four self-adhesive rubber feet are included with the DA. For
tabletop use, attach one foot at each corner of the bottom side of
the unit and place the unit in the desired location.
Rack mounting
For optional rack mounting, do not install the rubber feet.
Mount the DA on a standard or basic 1U 6" deep rack shelf
(Extron part #60-190-10 or #60-604-10) or a standard or basic 1U
Universal rack shelf (Extron part #60-190-01 or #60-604-01). On
the Universal rack shelves, the DA mounts in one of two
locations to the rear of the rack or in one of two locations to the
front of the rack.
1. Remove rubber feet if they were previously installed on
the bottom of the DA.
2. Mount the DA on the rack shelf, using two
4-40 x 3/16" screws in opposite (diagonal) corners to
secure it to the shelf (figure 3 and figure 4).
3. Install blank panel(s) or other unit(s) on the rack shelf.
VersaTools
®
MTP DA4 and MTP DA8 • Installation 76 VersaTools
®
MTP DA4 and MTP DA8 • Installation