Extron electronic SW8/12 VGA Switch User Manual


 
2-13
SW8/12 VGA Ars • Installation and Operation
Front Panel
The SW8/12 VGA Ars switcher front panel controls are described below.
ACTIVE
SW8 VGA Ars
1 2 3 4 5 6 7 8
AUTO SWITCH
MODE NORMAL AUTO
1
3
2
4 5
Figure 2-17 — SW8 VGA Ars front panel
AUTO SWITCH
ACTIVE
MODE NORMALAUTO
SW 12 VGA Ars
1 2 3 4 5 6 7 8 9 10 11 12
1
3
2
4 5
Figure 2-18 — SW12 VGA Ars front panel
a
Auto switch active LED —Lightswhentheautoswitchmodeisenabled.
b
Input buttons and LEDs— Dependingonthemodelthereareeightortwelve
inputbuttonsandcorrespondingLEDs.Toselectaninput,pressthedesired
inputbutton.TheadjacentLEDlights.
c
Mode (Input 1) button — The Mode button functions in conjunction with
otherbuttonsasshowninthetablebelow.Modeisasecondaryfunctionof
theInput1button.
Hold Press Description and Result
Mode Normal Enable Normal mode — Front panel input buttons operate normally.
AutoSwitchActiveLEDisoff.
Mode Auto Enable Auto switch mode Front panel input buttons are locked out.
Switcheroutputshighestnumberinputthathasasyncsignalpresent.If
no sync signal is present, input #1 is selected by default.
AutoSwitchActiveLEDison.
Mode Inputbutton
#4for3sec.
Enable/disable Executive mode AllLEDsash3times.Allfrontpanel
input buttons are locked out. Attempts to select an input button causes
allLEDstoash.
InputselectionsviaRS-232andVSWIAAPstillfunction.
Disable Executive mode AllLEDsashthreetimes,andthefront
panel input buttons return to operation.
Mode-whileapplying
power
Perform factory reset Reset unit to its factory settings.
d
Normal (Input 2) button —HoldMode and press Normal to have the front
panel input buttons operate in manual mode - press an input button to select
an input signal.