POWER
12V
0.5A MAX
INPUT
AUDIO
VIDEO
OUTPUT
DC Power Cord
Captive Screw
Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
AA
Captive
Screw
Connector
Tie Wrap
3"
16 (5 mm) Max.
Figure 3. PowerSupplyWiring
CAUTION: Always use a power supply supplied or specified by Extron. Use
of an unauthorized power supply voids all regulatory compliance
certification and may cause damage to the supply and the
TLP VIM.
Extron power supplies are certified to UL/CSA 60950-1 and
are classified as LPS (limited power source). Use of a non-LPS
or unlisted power supply will void all regulatory compliance
certification.
Unless otherwise stated, the AC/DC adapters are not suitable for
use in air handling spaces or in wall cavities. The power supply is
to be located within the same vicinity as the Extron A/V processing
equipment in an ordinary location, Pollution Degree 2, secured to
the equipment rack within the dedicated closet, podium or desk.
The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75, and
the Canadian Electrical Code, part 1, section 16. The power supply
shall not be permanently fixed to building structure or similar
structure.
c
Audioinput One 3-pole captive screw connector for inputting
balanced or unbalanced audio. The audio input is mono only and
either balanced or unbalanced.
Balanced InputUnbalanced Input
Tip
Ring
Sleeve
Tip
Sleeve
Figure 4. AudioInputConnectorWiring