4. Line up the rack-mount bracket holes to the holes on the rack and ensure that the
FortiSwitch unit is level.
5. Finger tighten four rack-mount screws to attach the unit to the rack.
6. Verify that the spacing around the FortiSwitch unit conforms to requirements and that
the unit is level, then tighten the rack-mount screws with an appropriate screwdriver.
7. Using the provided power cable, plug the cable into the rear of the unit, and then into
a grounded electrical outlet or a separate power source such as an uninterruptible
power supply (UPS) or a power distribution unit (PDU).
To install the unit on a at surface
1. Ensure that the surface onto which the FortiSwitch unit to be installed is clean, level,
and stable and that there is at least 1.5in (3.8cm) of clearance on all sides to allow
for adequate airflow.
2. Attach the provided rubber feet to the bottom of the FortiSwitch unit.
3. Place the unit in the designated location.
4. Verify that the spacing around the FortiSwitch unit conforms to requirements and that
the unit is level.
5. Using the provided power cable, plug the cable into the rear of the unit, and then into
a grounded electrical outlet or a separate power source such as an uninterruptible
power supply (UPS) or a power distribution unit (PDU).
1.5in
1.5in