Fortinet 5050 Network Card User Manual


 
Connecting the FortiGate-5050 chassis to AC power using the FortiGate-5053 power converter tray
FortiGate-5050 Chassis Guide
18 01-30000-87211-20090106
http://docs.fortinet.com/Feedback
Figure 10: Non-redundant power for all FortiGate-5050 chassis slots
Redundant FortiGate-5050 power supplies
You can supply redundant power to a FortiGate-5050 chassis by adding a third
FortiGate-5020/5050 power supply to the FortiGate-5053 power converter tray
(see Figure 11). If one of the FortiGate-5020/5050 power supplies in the FortiGate-5053
power converter tray fails, the third power supply takes its place without a power
interruption.
Figure 11: 2 + 1 redundant FortiGate-5020/5050 power supplies
Redundant FortiGate-5053 power converter trays
A single FortiGate-5053 power converter tray is usually only connected to one
FortiGate-5050 power input connector. If this power input connector or FortiGate-5053
power converter tray fails or is disconnected the FortiGate-5050 chassis will loose power.
You can supply redundant power to the entire FortiGate-5050 chassis by adding a second
FortiGate-5053 power converter containing two or three FortiGate-5020/5050 power
supplies and connected this FortiGate-5053 power converter tray to the second
FortiGate-5050 power input connector.
Slot 1Slot 2Slot 3
1 FortiGate-5053
power convertor tray
2 FortiGate-5020/5050
power supplies
2 x 800W = 1600W
1 FortiGate-5050
chassis
1
2
2
3
4
5
ShMC
1
ShMC
POWER
Hot Swap
Status
Alarm
Minor
Console Ethernet
Alarm
Reset
Critical
Major
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
1514
1312
1110
98
76
54
32
10
E2
OKCLK
INTEXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
1514
1312
1110
98
76
54
32
10
E2
OKCLK
INTEXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
PWR
STAIPM
CONSOLE
USB
1 2 3 4 5 6 7 8
ACC
PWR
STAIPM
CONSOLE
USB
1 2 3 4 5 6 7 8
ACC
PWR
STAIPM
CONSOLE
USB
1 2 3 4 5 6 7 8
ACC
Slot 1Slot 2Slot 3
1 FortiGate-5053
power convertor tray
3 FortiGate-5020/5050
power supplies
2 x 800W = 1600W
2 + 1 redundancy
1 FortiGate-5050
chassis
1
2
2
3
4
5
ShMC
1
ShMC
POWER
Hot Swap
Status
Alarm
Minor
Console Ethernet
Alarm
Reset
Critical
Major
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
1514
1312
1110
98
76
54
32
10
E2
OKCLK
INTEXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
1514
1312
1110
98
76
54
32
10
E2
OKCLK
INTEXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
PWR
STAIPM
CONSOLE
USB
1 2 3 4 5 6 7 8
ACC
PWR
STAIPM
CONSOLE
USB
1 2 3 4 5 6 7 8
ACC
PWR
STAIPM
CONSOLE
USB
1 2 3 4 5 6 7 8
ACC