C120-E361-04EN A-1
Appendix A Troubleshooting
A
This appendix explains how to deal with possible problems during the RCI setup.
z In the Case Where Setrci Command Ended Abnormally and Displayed “Operation
Failed Error Status: XX”
z In the Case Where RCI Status of RCI Host Changes From ACTIVE to INACTIVE
A.1 In the Case Where Setrci Command Ended
Abnormally and Displayed “Operation Failed
Error Status: XX”
When the RCI construction by the setrci command ended abnormally and "Operation
failed error status: XX" is displayed, the displayed error status code, explanation, and
remedy pattern are described to the following table.
Table A.1 The Error Status Code and Explanation
Code Explanation
Remedy
pattarn
00 Detected the duplicate RCI address. Pattern A
01 RCI address of current unit is not configured or false. Pattern B
02 Detected the duplicate RCI address of RCI host, or detected the
undefined RCI address.
Pattern C
03 RCI address of current unit is not configured. Pattern B
04 Over maximum entry of RCI table. Pattern D
05 Detected anomaly in RCI table receiving. Pattern C
06 Detected anomaly in RCI table sending. Pattern C
07 Receiving status check from undefined RCI device. Pattern C
08 Detected the loss of RCI master. Pattern C
09 Detected anomaly of RCI table. Pattern C
0a Synchronous time out of RCI table. Pattern C
0b Synchronous retry out of RCI table. Pattern C
0c Detected anomaly of RCI table. Pattern C
0d Failed the version check of RCI table. Pattern C
0e Detected anomaly of RCI table. Pattern C
0f Detected anomaly in synchronous with RCI Neuron chip. Pattern E