Name Command Contents
Carriage return LF, CR Prints buffer data and return the line.
Double width print set SO Sets the double width character.
Power-down mode set DC2, DC3 Reduces the power consumption during standing
by.
Double width print reset DC4 Resets the double with character.
ESC sequence entry ESC Indicates the start of an escape sequence formed
by this code plus subsequent commands.
Line space set ESC A + n Sets the line space length in 2 × (0 to 255 dot
lines).
Paper feed set in normal direction ESC B + n Sets the paper feed in normal direction.
(Feeding range: 2 × (0 to 255 dot lines))
Bit image print set ESC K +n1+n2+n3 Sets the bit image printing in single or double
density mode.
International character set ESC R+n Selects the international characters.
Download character register ESC &+n1+n2+~ Registers the download characters of 12 × 6 or 16
× 8 dots.
Printing quality set ESC Q+n+SP*+~ Sets the printing quality conforming to used paper.
Printing density set ESC Q+n+!+A Sets the printing density mode.
(Single density standard, reduced or double
density)
Paper feed set in reverse direction ESC j+n Sets the paper feed in reverse direction.
(Feeding range: 2 × (1 to 255 dot lines))
Character grade set ESC x+n Sets the character grade in standard or high
grade.
Special character print set ESC ¥+n Prints the special character.
Start position set for bit-image printing ESC 1+n Sets the print start position of bit-image printing in
left end.
Detecting function set ESC 9+n Sets the detecting function.
Mark detection ESC FF Feeds the paper to the marking position.
Line feed length set after mark detection ESC w+n Sets the line feed length after mark detection.
Automatic paper loading length set ESC EM+n Sets paper feeding length for automatic paper
loading.
Automatic printing speed set ESC s+n Sets the function mode in the automatic printing
speed set.
Printer initialization ESC @ Initializes the printer MPU.
PRINTING COMMANDS (CENTRONICS STANDARD INTERFACE)
Notes:
*: “SP” means the space code (20H).
Bus interface uses different commands.