Fujitsu MAE3182LC Computer Drive User Manual


 
C141-E064-03EN4 - 10
(3) Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
3 cm from the disk drive. At designing the system cabinet, consider following points.
Make a suitable air flow so that the DE surface temperature does not exceed 55°C.
CAUTION
Heat
An air flow with an adequate wind velocity must be maintained to
deal with much heat generated from the MAF3364xx.
Reference value: An air flow with a wind velocity of more than
0.5 m/s is required in an environment at 40°C,
and an air flow with a wind velocity of more
than 1.0m/s in an environment at 45°C (Center
of DE cover 55°C).
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling
effect by measuring temperature of specific ICs and the DE. These measurement results
should be within a criteria listed in Table 4.1.
Table 4.1 Surface temperature check point
No. Measurement point Criteria
1 Center of DE cover 55°C
2 Read channel LSI 83°C
3 VCM/SPM Driver 75°C
4 HDC 85°C
Figure 4.10 Surface temperature measurement points (MAF series, MAE series, MAG series)