4-20 C141-E201
4.3.3 Cable connector requirements
Table 4.2 lists the recommended components cable connection.
Table 4.2 Recommended components for connection
Applicable
model
Name
Par number
(Size)
Manufacturer
Reference
(*1)
787311-1
Tyco Electronics
AMP
NC
SCSI connector
(CN1)
Connector
87689-0001 Molex
DHJ-PAC68-2AN DDK
Cable socket
(closed-end type)
786090-7
Tyco Electronics
AMP
SCSI cable (CN1)
Signal cable
UL20528-FRX-68-
P0.635
Fujikura
S1
Cable socket housing
1-480424-0
Tyco Electronics
AMP
Contact
170148-1
Tyco Electronics
AMP
Power supply
cable (CN1)
Cable (AWG18 to 24)
S2
Cable socket housing
A3B-12D-2C
HIROSE
ELECTRIC
Contact
A3B-2630SCC
HIROSE
ELECTRIC
External operator
panel (CN1)
Cable (AWG26 to 36)
S3
Cable socket housing
FCN-723J024/2M
FUJITSU
TAKAMIZAWA
Contact
FCN-723J-G/AM
FUJITSU
TAKAMIZAWA
NP
External operator
panel (CN2)
Cable (AWG28)
S4
(*1) See Figure 4.22.
(1) SCSI cable
See Section 1.3, “Physical Requirements”, and Section 1.4, “Electrical Requirements”, in SCSI
Physical Interface Specifications.
(2) Power cable
IDDs must be star-connected to the DC power supply (one to one connection) to reduce the
influence of load variations.
(3) DC ground
The DC ground cable must always be connected to the IDD because no fasten tab dedicated to SG
is provided with the IDD. Therefore, when SG and FG are connected in the system, it is necessary
to connect SG and FG at the power supply or to connect SG of the power supply to FG of the
system.