Fujitsu MBA3300RC Computer Drive User Manual


 
6.2 INIT Error Recovery Methods (Recommended)
C141-C013 377
Table 6.5 Sense data error classification (3/3)
K* C* Q*
Outline of Error
L*
Recovery Method
(See Table 6.6.)
6 29 xx Power on, reset, or HARD RESET occurred None 14
The HDD was initialized by a Power on or HARD RESET
sequence.
6 2A 01 Mode parameters changed None 21
The MODE SELECT parameters were changed by
another INIT.
6 2F 00 Commands cleared by another INIT None 25
Commands were cleared by another INIT.
6 3F 01 Microcode has been changed None 27
02 Changed operation definition
7
27
00
Write protected
None
15
Access to a read protected or write protected.
B 03 xx Peripheral device write fault Need 12
11 xx Unrecovered read error
13 xx Sync byte not found for data field
14 xx Record not found
15 xx Mechanical positioning error
01 Information Unit Too Short B 0E
02 Information Unit Too Long
47 01 Information Unit iuCRC Error Detected Need 6
4B 01 Invalid Target Port Transfer Tag Received
4B 02 Too Much Write Data
4B 03 ACK/NAK Time Out
4B 04 NAK Received
4B 05 Data Offset Error
4B 06 Initiator Response Timeout
An unrecoverable SAS related error occurred in the
command execution sequence.
B 4E 00 Overlapped commands attempted None 2
Before execution of a command was completed, a new
command was issued by the same INIT.
E 1D 00 Miscompare during verify operation None 24
Data failed to match in the Byte check mode of the
Verify command.
* K: Sense Key C: Additional Sense Code
Q: Additional Sense Code Qualifier L: Logging Necessary? (shown in Section 6.2.3)