Fujitsu MCE3064AP Computer Drive User Manual


 
4 - 74 C156-E142-02EN
4.6.26 WRITE LONG command
Table 4.113 WRITE LONG command
Bit
Byte
76543210
0 Operation Code (3Fh)
1 Logical Unit Number Reserved
2-5 Logial Block Address
6 Reserved
7-8 Byte Transfer Length
9-11 Reserved
The WRITE LONG command writes data in the data, CRC, and ECC sections to the specified
logical block address.
The transfer byte length must be a multiple of 600 (X'258') bytes for 512 byte media and a multiple
of 2380 (X'94C') bytes for 2048 byte media.