Fujitsu MHA2032AT Computer Drive User Manual


 
Interface
5-48 C141-E042-01EN
Sector Count register value Point of timer
0 [X’00’] 30 minutes
1 to 3 [X’01’ to X’03’] 15 seconds
4 to 240 [X’04’ to X’F0’]
(Value ×5) seconds
241 to 251 [X’F1’ to X’FB’] 30 minutes
252 [X’FC’] 21 minutes
253 [X’FD’] 30 minutes
254 to 255 [X’FE’ to X’FF’] 21 minutes 15 seconds
attention: The automatic power-down is excuted if no command is coming for
30 min. (default)
At command issuance (I/O registers setting contents)
1F7
H
(CM) X’97’ or X’E3’
1F6
H
(DH)
×××
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
Period of timer
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST) Status information
1F6
H
(DH)
×××
DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
xx
Error information