![](http://pdfasset.owneriq.net/e/3f/e3fbdbd0-0ca1-4a92-902b-e5b5f426de07/e3fbdbd0-0ca1-4a92-902b-e5b5f426de07-bg25.png)
Appendix A Restoration Procedure for when a Path Degrades in a VERITAS Volume
Manager Environment
>
ETERNUS DX Disk storage systems Server Connection Guide (Fibre Channel) for Linux
37
Copyright 2010 FUJITSU LIMITED
P3AM-3842-05ENZ0
4 Check the volume status.
Check that the status of a volume that was "DISABLED" in Step 1-2 is changed to
"ENABLED".
Example (for ETERNUS DX410)
End of procedure
# vxdmpadm getsubpaths ctlr=c<controller number>
# vxdmpadm getsubpaths ctlr=c7
NAME STATE PATH-TYPE DMPNODENAME ENCLR-TYPE ENCLR-NAME
==========================================================================
sde ENABLED - sdb FJ_DX400 fj_dx400
sdf ENABLED - sdc FJ_DX400 fj_dx400
sdg ENABLED - sdd FJ_DX400 fj_dx400