Fujitsu TX200 S6 Server User Manual


 
60 Operating Manual TX200 S6
Hardware installation
Connecting the monitor
Ê Connect the monitor to the video connector of the server (see figure 9 on
page 59).
Ê Connect the power cable of the monitor to a grounded mains outlet of the in-
house mains and/or to the mains socket strip of the rack.
V CAUTION!
The rated current for the monitor is indicated on the technical data label
on the monitor or in the operating manual for the monitor.
4.5 Connecting the server to the mains
The server is either equipped with a standard power supply unit or with one or
two hot-plug power supply units.
As an option, the standard power supply unit can be replaced with a hot-plug
power supply unit. A second hot-plug power supply unit can be added to ensure
a redundant power supply. If a defect occurs in one power supply unit, the other
power supply unit ensures unimpaired further operation.
V CAUTION!
The server is automatically set to a mains voltage in the range 100 V -
240 V. You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
I A phase redundancy in the power supply of the server can be set up if
two hot-plug power supply units are installed.
In this case the two power supply units are directly connected either to
two different phases or two different power circuits of the in-house mains.