78 Operating Manual TX200 S6
Starting up and operation
I If the operating system does not switch the server off automatically, press
the On/Off button for at least four seconds and/or send a control signal
for power button override.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
– Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S2, you can configure
that the server is switched on/off controlled by timer.
– Ring indicator
The server is switched on by an internal or external modem.
– Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
– After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC S2).
– Power button override
The system can be switched off by pressing and holding down the On/Off
button (for approximately 4 - 5 seconds).
V CAUTION!
There is a risk that data may be lost.
– iRMC S2
iRMC S2 offers various options for switching the server on and off, e.g. via
the Power On Off page of the iRMC S2 Web interface.