Fujitsu Tx200-s3 Personal Computer User Manual


 
*1. By applying Internal HDD Unit Bay Conversion kit (PG-BC103), 5 inch bay x 2 can be converted
to 3.5 inch bay x 2.
When Internal HDD Unit Bay Conversion kit (PG-BC103) is applied, Internal Backup Device
cannot be mounted on 5inch Bay.
*2. By applying Power Supply Conversion kit (PGBRSU104), non-redundant structure (Power Supply x1,
FAN x2) can be converted to redundant structure (Power Supply x2, FAN x6).
*3. Frequency will be changed by the spec of PCI card and number of cards mounted.
*Components installed as standard configuration marked in grey.
PCI Slot
* No AFT/ALB Support
* [n] : Installation Priority
* # : standard
* - : cannot be installed
*1.Frequenc
y
will be chan
g
ed b
y
the spec of PCI card and number of cards mounted.
-
Eth. Ctrl 1x1Gbit PCI-E
1000BASE-SX
PG-288
PCI Express
(x4)
- - [1] [2]
-
[2]
[2] 2
2
PCI Express Card
- PCI Express Card
PCI Express Card
- PCI Express Card
-
2
2
[3]
Internal/External SCSI
Controller
Fibre Channel Controller
PG-FC202 /
PGBFC202
PCI Express
(x4)
- - - [1] [2]
[2] [1] - -SCSI Ctrl U160
PG-1281 /
PGB1281
PCI/64bit -
[2] [1] - -
-
RAID Ctrl 2-Channel 128MB
w/ BBU
PG-142E3 /
PGB142E3
PCI/64bit -
Eth. Ctrl 2x1Gbit PCI-X
1000-BASE-T
PG-1863 PCI-X/64bit - [1] [2] - -
-
[3][1] [2] - -
[3]-
-
Eth. Ctrl 1000-BASE-T Cu
PG-1892 /
PGB1892
PCI-X/64bit -
-
[3]
Internal array
External array
2
[3] 2
[3] 2
Standard, Internal array1
PG-140G /
PGB140G
PCI-X/64bit - [1] - - -
Internal arraySAS RAID Ctrl
PG-140F /
PGB140F
PCI-X/64bit
-
SAS Controller
(8ports)
- PCI-X/64bit #
-
Remarks
1012345
PCI-X PCI Express PCI
x8
lane
x4
lane
32bit/
33MHz
Full Height
Mountable Cards Bus
64bit/
100MHz
64bit/
100MHz *1
3.3V
Mount
Priority
Eth. Ctrl 2x1Gbit PCI-E
1000-BASE-T
PG-2861 /
PGB2861
PCI Express
(x4)
---[1]
[1] -
[1] [2] -
[1] [2]
Max No.
of Mount
3
2
2
1
1
1
2
2
-
x8 socket
5.0V
-
---
---
SAS RAID Ctrl
Eth. Ctrl 1x1Gbit PCI-E
1000-BASE-T
PG-289 /
PGB289
PCI Express
(x1)
Eth. Ctrl 1x1Gbit PCI
1000-BASE-T
PG-1853 /
PGB1853
PCI/32bit
Eth. Ctrl 1000-BASE-SX
Fibre LC
PG-1882 PCI-X/64bit
---[1]
Configuration Diagram
Power Supply Unit
PCI Slots
5 inch Bay 3
5 inch Bay 2
5 inch Bay 1
CD-ROM Drive / FDD
Mountable I/O Options
PRIMERGY TX200 S3
Memory
DIMM Slot 3B
DIMM Slot 2B
DIMM Slot 1B
DIMM Slot 3A
DIMM Slot 2A
Power Supply Unit
DIMM Slot 1A
CPU
Xeon®
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
3.5 inch HDD Bay 6
(hot plug)
3.5 inch HDD Bay 5
(hot plug)
3.5 inch HDD Bay 4
(hot plug)
3.5 inch HDD Bay 3
(hot plug)
3.5 inch HDD Bay 2
(hot plug)
3.5 inch HDD Bay 1
(hot plug)
*2
*1
Bay 6
SAS
Bay 5
SAS
Bay 4
SAS
Bay 3
SAS
Bay 2
SAS
Bay 1
SAS
Hard Disk 3.5inch Bay (hot plug)
Standard Drive Cage ( HDD x 6ports )
Bay 7
SAS
Bay 8
SAS
When Internal HDD Unit Bay Conversion kit (PG-
BC103) is applied. ( HDD x 2ports )
Internal Backup Device cannot be mounted
because 5inch Bay x 2 is used by HDDs.
PCI5 PCI 32bit/33MHz
PCI4 PCI Express (x4)
PCI2 PCI-X 64bit/100MHz *3
PCI3 PCI Express (x8)
PCI1 PCI-X 64bit/100MHz *3
PCI10 PCI-X 64bit/100MHz
High
Low
Xeon®
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
High
Low