Fujitsu Tx200-s3 Personal Computer User Manual


 
If you would like to order internal HDDs and internal backup devices, please order optional cards/cables according to the following table.
Standard Drive Cage
(6bays)
Standard Drive Cage
(6bays)
(''1) USB Backup Devices: PG-DT504
(''2) SCSI Wide Backup Devices: PG-LT302/PG-LT201/PGBLT201C1/PG-LT102
(''3) If you order internal backup devices by CTO, SCSI cable is attached with backup devices.
HDD SAS 15k 73GB hot plug 3.5inch
SAS Controller PG-HDB75A
( installed as standard ) PGBHDB75A (for CTO)
*. In case that SAS Controller installed
as standard is used for RAID configuration, HDD SAS 15k 147GB hot plug 3.5inch
only 2 HDDs of same capacity and same Internal HDD Unit Bay PG-HDB45A
rpm can be connected. Conversion kit PGBHDB45A (for CTO)
*. RAID1 configuration can be set. PG-BC103
*. Hot spare disk cannot be set.
HDD SAS 15k 300GB hot plug 3.5inch
PG-HDB35A
PGBHDB35A (for CTO)
*. When Internal HDD Unit Bay Conversion kit
SAS RAID Ctrl (PG-BC103) is applied, up to 8 Internal HDDs
(without BBU) can be mounted but internal backup devices
PG-140F cannot be mounted on 5inch Bays.
PGB140F (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
To set RAID configuration, two or more HDDs
which are same capacity and same rpm
should be connected to SAS Controller
installed as standard.
SAS RAID Ctrl
(with BBU)
PG-140G
PGB140G (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
To set RAID configuration, two or more HDDs
which are same capacity and same rpm
should be connected to SAS Controller
installed as standard.
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
Drive Cage
-
(not connect)
RAID
SAS Controller (standard)
*. In case that SAS Controller installed as standard
is used for RAID configuration, only 2 HDDs of same
capacity and same rpm can be connected.
Type of HDD connection
Interface
SAS Controller (standard)
*. Only SAS Configuration is supported.
Onboard USB
(internal port)
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
SAS /
RAID
Internal Backup Devices PRIMERGY TX200 S3
SCSI Card (PG-1281/PGB1281)
SCSI Cable (PG-CBLS025) (''3)
Onboard USB
(internal port)
Connection
SCSI Card (PG-1281/PGB1281)
SCSI Cable (PG-CBLS025) (''3)
-
(not connect)
USB (''1) Connection SCSI Wide (''2) Connection
-
(not connect)
-
(not connect)
Connecting Internal HDD and Internal Backup Devices
SAS / RAID Configuration
Internal HDD
PCI Bus
RAID Configuration
PCI Bus
PRIMERGY TX200 S3